HZYN-1301 ASTM D445 automatikus olajkinematikus viszkoziméter
HZYN-1301 kinematikus viszkozitású fürdő Astm D445 olaj kinematikus viszkoziméter
Vázlat
This Kinematic Viscometer is designed and manufactured specially according to the national standard "GB265 – 88 Determination of kinematic viscosity of petroleum products" . It's suitable to determine kinematic viscosity of liquid petroleum products. This apparatus has the function of timing of the trial sample movement and can calculate the final result of kinematic viscosity. This method is suitable to determine kinematic viscosity of liquid petroleum products ( It refers to Newtonian liquids ), and its unit is m2/s. Generally in actual utilization, the unit is mm2/s. The dynamic viscosity is equal with the result which use kinematic viscosity to multiply the density of the liquid. By this method, it can determine the time that the liquid with the certain volume flows past the calibrated glass capillary viscometer under the gravity in the certain stable temperature and the value that the constant value of capillary in the viscometer multiplies the flowing time, that is , the determined kinematic viscosity of liquid at the temperature. At the temperature, the value that kinematic viscosity multiplies the density of the liquid in the same temperature is the dynamic viscosity at the temperature.

Tech Data
Folyékony fürdőnyílások | 4 |
Tartomány a hőmérséklet szabályozásához | Indoor temperature—120 degree |
Pontosság a hőmérséklet szabályozásához | Room temperature -120 degree Less than or equal to ±0.1 degree |
Szobahőmérséklet | -40 degree Less than or equal to ±0.2 degree |
Bemeneti áramforrás | AC220V±10V, 50HZ |
Fűtési teljesítmény | 1000W |
Tesztidők | 1-6 alkalommal állítható. |





Felhasználási feltételek
(1) Környezeti hőmérséklet: 0 fok -40 fok
(2) Relatív páratartalom:<>
Figyelem
(1). Ha nincs víz az akváriumban, megtiltja a bekapcsolást.
(2). In the liquid of the bathtub, there can't be impurities and floating materials in order to avoid to block the test holes. For the new bath liquid , it often appears bubbles when heating, which will affect the test, especially when it appears bubbles in the test holes, it will have the most serious affect. Please loose the capillary to check if there is bubble in the test holes. If it appears, please use the hose to blow in order to get rid of the bubbles or use the clean the toothbrush to wash off the bubbles.
(3). A készülék használata előtt gondoskodnunk kell a megbízható földelésről.
(4). Amikor újra-indítjuk a készüléket, a használat időtartamának 15 percnél hosszabbnak kell lennie. A készüléket pedig hidegfürdős állapotban indítjuk be, és 45 perc után kell használni.
(5). When we rectify the temperature with the full-immersion thermometer, the effective scale of the thermometer can't be exposed to the liquid level of the constant temperature bath.
(6). Tilos a készüléket korrozív gázzal nedves környezetben tárolni vagy használni.
(7). A kapilláris rögzítésekor ügyeljen a felső nyílás magasságára, és ne kerüljön víz a kémcsőbe.
(8). Időszakos használat után, vagy ha úgy találjuk, hogy az olajszint mérése érzéketlen, időben tisztítsuk meg a tesztkapocs mérőfuratait.
(9). During using the apparatus, if appears fault, you should invite the professionals to repair and contact with us in time. If it's quality problem, we can offer the gratuitous warranty within one year.
(10). Az áramforráshoz meg kell tartani a jó földelést.



Népszerű tags: HZYN-1301 ASTM D445 automata olaj kinematikus viszkoziméter, Kína, beszállítók, gyártók, ár, eladó, kinematikus viszkoziméter, kinematikus viszkoziméter kőolajtermékekhez, automatikus hordozható kinematikus viszkoziméter, kinematikus viszkoziméter fürdő, kinematikus viszkoziméter digitális fürdővel, ISO3104 kinematikus viszkoziméter, ISO3104 nyers viszkoziméter , hzyn-1301, kinetikus viszkozitásmérő, bitumen kinematikai viszkozitás vizsgálata, szigetelőolaj kinematikus viszkoziméter, kinematikus viszkoziméter, motorolaj viszkozitásmérő